Characterisation of radiation damage in silicon photomultipliers with a Monte Carlo model
- Publication type:
- Journal article
- Metadata:
-
- Autoren
- S Sanchez Majos
- P Achenbach
- J Pochodzalla
- Autoren-URL
- https://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=fis-test-1&SrcAuth=WosAPI&KeyUT=WOS:000259848900005&DestLinkType=FullRecord&DestApp=WOS_CPL
- DOI
- 10.1016/j.nima.2008.06.021
- Externe Identifier
- Clarivate Analytics Document Solution ID: 357MC
- ISSN
- 0168-9002
- Ausgabe der Veröffentlichung
- 3
- Zeitschrift
- NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
- Schlüsselwörter
- silicon photomultiplier
- Monte Carlo model for detector output
- single-electron response function
- radiation damage
- Paginierung
- 351 - 357
- Datum der Veröffentlichung
- 2008
- Status
- Published
- Titel
- Characterisation of radiation damage in silicon photomultipliers with a Monte Carlo model
- Sub types
- Article
- Ausgabe der Zeitschrift
- 594
Data source: Web of Science (Lite)
- Other metadata sources:
-
- Autoren
- S Sánchez Majos
- P Achenbach
- J Pochodzalla
- DOI
- 10.1016/j.nima.2008.06.021
- ISSN
- 0168-9002
- Ausgabe der Veröffentlichung
- 3
- Zeitschrift
- Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Sprache
- en
- Paginierung
- 351 - 357
- Datum der Veröffentlichung
- 2008
- Status
- Published
- Herausgeber
- Elsevier BV
- Herausgeber URL
- http://dx.doi.org/10.1016/j.nima.2008.06.021
- Datum der Datenerfassung
- 2018
- Titel
- Characterisation of radiation damage in silicon photomultipliers with a Monte Carlo model
- Ausgabe der Zeitschrift
- 594
Data source: Crossref
- Abstract
- Measured response functions and low photon yield spectra of silicon photomultipliers (SiPM) were compared to multi-photoelectron pulse-height distributions generated by a Monte Carlo model. Characteristic parameters for SiPM were derived. The devices were irradiated with 14 MeV electrons at the Mainz microtron MAMI. It is shown that the first noticeable damage consists of an increase in the rate of dark pulses and the loss of uniformity in the pixel gains. Higher radiation doses reduced also the photon detection efficiency. The results are especially relevant for applications of SiPM in fibre detectors at high luminosity experiments.
- Autoren
- S Sanchez Majos
- P Achenbach
- J Pochodzalla
- Autoren-URL
- http://arxiv.org/abs/0805.4158v1
- Zeitschrift
- Nucl.Instrum.Meth.A
- Schlüsselwörter
- nucl-ex
- nucl-ex
- Notes
- submitted to Nucl. Instr. and Meth. A
- Paginierung
- 351 - 357
- Datum der Veröffentlichung
- 2008
- Herausgeber URL
- http://dx.doi.org/10.1016/j.nima.2008.06.021
- Datum der Datenerfassung
- 2008
- Datum, an dem der Datensatz öffentlich gemacht wurde
- 2008
- Titel
- Characterisation of radiation damage in silicon photomultipliers with a Monte Carlo model
- Ausgabe der Zeitschrift
- 594
Files
0805.4158v1.pdf
Data source: arXiv
- Beziehungen:
- Property of