Integrated setup for the fabrication and measurement of magnetoresistive nanoconstrictions in ultrahigh vacuum
- Publication type:
- Journal article
- Metadata:
-
- Autoren
- Daniel Stickler
- Robert Froemter
- Wei Li
- Andre Kobs
- Hans Peter Oepen
- Autoren-URL
- https://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=fis-test-1&SrcAuth=WosAPI&KeyUT=WOS:000260573500029&DestLinkType=FullRecord&DestApp=WOS_CPL
- DOI
- 10.1063/1.2981693
- Externe Identifier
- Clarivate Analytics Document Solution ID: 367ST
- PubMed Identifier: 19044723
- ISSN
- 0034-6748
- Ausgabe der Veröffentlichung
- 10
- Zeitschrift
- REVIEW OF SCIENTIFIC INSTRUMENTS
- Schlüsselwörter
- focused ion beam technology
- magnetic thin films
- magnetoresistance
- micromanipulators
- nanostructured materials
- nanotechnology
- Permalloy
- scanning electron microscopes
- vacuum apparatus
- Artikelnummer
- ARTN 103901
- Datum der Veröffentlichung
- 2008
- Status
- Published
- Titel
- Integrated setup for the fabrication and measurement of magnetoresistive nanoconstrictions in ultrahigh vacuum
- Sub types
- Article
- Ausgabe der Zeitschrift
- 79
Data source: Web of Science (Lite)
- Other metadata sources:
-
- Abstract
- <jats:p>A UHV instrument is presented for in situ fabrication of nanostructures and in situ investigation of their magnetoresistance. Nanostructures of diverse shape and size are created from thin films utilizing a focused ion beam. The magnetic nanostructures are contacted via a micromanipulator, which makes it possible to address the individual structures. The system is additionally equipped with a scanning electron microscope column, which is used for damage-free navigation and control of the structuring and contacting. First magnetoresistance measurements of structures carved into a Permalloy film demonstrate the high sensitivity and the flexibility of the new setup.</jats:p>
- Autoren
- Daniel Stickler
- Robert Frömter
- Wei Li
- André Kobs
- Hans Peter Oepen
- DOI
- 10.1063/1.2981693
- eISSN
- 1089-7623
- ISSN
- 0034-6748
- Ausgabe der Veröffentlichung
- 10
- Zeitschrift
- Review of Scientific Instruments
- Sprache
- en
- Online publication date
- 2008
- Datum der Veröffentlichung
- 2008
- Status
- Published
- Herausgeber
- AIP Publishing
- Herausgeber URL
- http://dx.doi.org/10.1063/1.2981693
- Datum der Datenerfassung
- 2023
- Titel
- Integrated setup for the fabrication and measurement of magnetoresistive nanoconstrictions in ultrahigh vacuum
- Ausgabe der Zeitschrift
- 79
Data source: Crossref
- Abstract
- A UHV instrument is presented for in situ fabrication of nanostructures and in situ investigation of their magnetoresistance. Nanostructures of diverse shape and size are created from thin films utilizing a focused ion beam. The magnetic nanostructures are contacted via a micromanipulator, which makes it possible to address the individual structures. The system is additionally equipped with a scanning electron microscope column, which is used for damage-free navigation and control of the structuring and contacting. First magnetoresistance measurements of structures carved into a Permalloy film demonstrate the high sensitivity and the flexibility of the new setup.
- Addresses
- Institut für Angewandte Physik, Universität Hamburg, Jungiusstr. 11, 20355 Hamburg, Germany. daniel.stickler@physnet.uni-hamburg.de
- Autoren
- Daniel Stickler
- Robert Frömter
- Wei Li
- André Kobs
- Hans Peter Oepen
- DOI
- 10.1063/1.2981693
- eISSN
- 1089-7623
- Externe Identifier
- PubMed Identifier: 19044723
- Open access
- false
- ISSN
- 0034-6748
- Ausgabe der Veröffentlichung
- 10
- Zeitschrift
- The Review of scientific instruments
- Sprache
- eng
- Medium
- Paginierung
- 103901
- Datum der Veröffentlichung
- 2008
- Status
- Published
- Datum der Datenerfassung
- 2008
- Titel
- Integrated setup for the fabrication and measurement of magnetoresistive nanoconstrictions in ultrahigh vacuum.
- Sub types
- Journal Article
- Ausgabe der Zeitschrift
- 79
Data source: Europe PubMed Central
- Abstract
- A UHV instrument is presented for in situ fabrication of nanostructures and in situ investigation of their magnetoresistance. Nanostructures of diverse shape and size are created from thin films utilizing a focused ion beam. The magnetic nanostructures are contacted via a micromanipulator, which makes it possible to address the individual structures. The system is additionally equipped with a scanning electron microscope column, which is used for damage-free navigation and control of the structuring and contacting. First magnetoresistance measurements of structures carved into a Permalloy film demonstrate the high sensitivity and the flexibility of the new setup.
- Autoren
- Daniel Stickler
- Robert Frömter
- Wei Li
- André Kobs
- Hans Peter Oepen
- Autoren-URL
- https://www.ncbi.nlm.nih.gov/pubmed/19044723
- DOI
- 10.1063/1.2981693
- eISSN
- 1089-7623
- Ausgabe der Veröffentlichung
- 10
- Zeitschrift
- Rev Sci Instrum
- Sprache
- eng
- Country
- United States
- Paginierung
- 103901
- Datum der Veröffentlichung
- 2008
- Status
- Published
- Datum, an dem der Datensatz öffentlich gemacht wurde
- 2009
- Titel
- Integrated setup for the fabrication and measurement of magnetoresistive nanoconstrictions in ultrahigh vacuum.
- Sub types
- Journal Article
- Ausgabe der Zeitschrift
- 79
Data source: PubMed
- Beziehungen:
- Property of