Synchrotron-based X-ray tomographic microscopy for visualization of three-dimensional collagen matrices
- Publication type:
- Journal article
- Metadata:
-
- Autoren
- AM Pabst
- W Wagner
- A Kasaj
- S Gebhardt
- M Ackermann
- A Astolfo
- F Marone
- D Haberthuer
- F Enzmann
- Moritz A Konerding
- Autoren-URL
- https://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=fis-test-1&SrcAuth=WosAPI&KeyUT=WOS:000350353300046&DestLinkType=FullRecord&DestApp=WOS_CPL
- DOI
- 10.1007/s00784-014-1312-4
- eISSN
- 1436-3771
- Externe Identifier
- Clarivate Analytics Document Solution ID: CC4VT
- PubMed Identifier: 25209594
- ISSN
- 1432-6981
- Ausgabe der Veröffentlichung
- 2
- Zeitschrift
- CLINICAL ORAL INVESTIGATIONS
- Schlüsselwörter
- Synchrotron radiation
- 3D visualization
- Morphometry
- Collagen matrix
- Paginierung
- 561 - 564
- Datum der Veröffentlichung
- 2015
- Status
- Published
- Titel
- Synchrotron-based X-ray tomographic microscopy for visualization of three-dimensional collagen matrices
- Sub types
- Article
- Ausgabe der Zeitschrift
- 19
Data source: Web of Science (Lite)
- Other metadata sources:
-
- Autoren
- AM Pabst
- W Wagner
- A Kasaj
- S Gebhardt
- M Ackermann
- A Astolfo
- F Marone
- D Haberthür
- F Enzmann
- Moritz A Konerding
- DOI
- 10.1007/s00784-014-1312-4
- eISSN
- 1436-3771
- ISSN
- 1432-6981
- Ausgabe der Veröffentlichung
- 2
- Zeitschrift
- Clinical Oral Investigations
- Sprache
- en
- Online publication date
- 2014
- Paginierung
- 561 - 564
- Datum der Veröffentlichung
- 2015
- Status
- Published
- Herausgeber
- Springer Science and Business Media LLC
- Herausgeber URL
- http://dx.doi.org/10.1007/s00784-014-1312-4
- Datum der Datenerfassung
- 2019
- Titel
- Synchrotron-based X-ray tomographic microscopy for visualization of three-dimensional collagen matrices
- Ausgabe der Zeitschrift
- 19
Data source: Crossref
- Abstract
- <h4>Introduction</h4>Three-dimensional collagen matrices (3D-CMs) may be visualized by cumbersome reconstructions of serial sections. We report here on the method of synchrotron-based X-ray tomographic microscopy (SRXTM) to image 3D-CMs in native tissue probes.<h4>Material and methods</h4>SRXTM of 3D-CMs (mucoderm®, mucograft®) was performed at the TOMCAT beamline of the Swiss Light Source (SLS) at the Paul Scherrer Institute (Villigen, Switzerland).<h4>Results</h4>SRXTM combines the advantages of high-resolution scanning electron microscopy (SEM) imaging with the low-resolution reconstructions of micro-CT (μCT) imaging. It may be used to non-destructively visualize and analyze structures within the 3D-CMs without the need of serial sectioning and reconstruction.<h4>Conclusion</h4>High-resolution SRXTM is a useful tool in analyzing the topology and morphometry of structures in 3D-CMs. The outcome justifies the efforts in sophisticated data processing.<h4>Clinical relevance</h4>SRXTM may help to understand the clinical characteristics of 3D-CMs in more detail.
- Addresses
- Institute of Functional and Clinical Anatomy, University Medical Center Mainz, Becherweg 13, 55099, Mainz, Germany.
- Autoren
- AM Pabst
- W Wagner
- A Kasaj
- S Gebhardt
- M Ackermann
- A Astolfo
- F Marone
- D Haberthür
- F Enzmann
- Moritz A Konerding
- DOI
- 10.1007/s00784-014-1312-4
- eISSN
- 1436-3771
- Externe Identifier
- PubMed Identifier: 25209594
- Open access
- false
- ISSN
- 1432-6981
- Ausgabe der Veröffentlichung
- 2
- Zeitschrift
- Clinical oral investigations
- Schlüsselwörter
- Collagen
- Tomography, X-Ray
- Synchrotrons
- Sprache
- eng
- Medium
- Print-Electronic
- Online publication date
- 2014
- Paginierung
- 561 - 564
- Datum der Veröffentlichung
- 2015
- Status
- Published
- Datum der Datenerfassung
- 2014
- Titel
- Synchrotron-based X-ray tomographic microscopy for visualization of three-dimensional collagen matrices.
- Sub types
- Research Support, Non-U.S. Gov't
- Journal Article
- Ausgabe der Zeitschrift
- 19
Data source: Europe PubMed Central
- Abstract
- INTRODUCTION: Three-dimensional collagen matrices (3D-CMs) may be visualized by cumbersome reconstructions of serial sections. We report here on the method of synchrotron-based X-ray tomographic microscopy (SRXTM) to image 3D-CMs in native tissue probes. MATERIAL AND METHODS: SRXTM of 3D-CMs (mucoderm®, mucograft®) was performed at the TOMCAT beamline of the Swiss Light Source (SLS) at the Paul Scherrer Institute (Villigen, Switzerland). RESULTS: SRXTM combines the advantages of high-resolution scanning electron microscopy (SEM) imaging with the low-resolution reconstructions of micro-CT (μCT) imaging. It may be used to non-destructively visualize and analyze structures within the 3D-CMs without the need of serial sectioning and reconstruction. CONCLUSION: High-resolution SRXTM is a useful tool in analyzing the topology and morphometry of structures in 3D-CMs. The outcome justifies the efforts in sophisticated data processing. CLINICAL RELEVANCE: SRXTM may help to understand the clinical characteristics of 3D-CMs in more detail.
- Date of acceptance
- 2014
- Autoren
- AM Pabst
- W Wagner
- A Kasaj
- S Gebhardt
- M Ackermann
- A Astolfo
- F Marone
- D Haberthür
- F Enzmann
- Moritz A Konerding
- Autoren-URL
- https://www.ncbi.nlm.nih.gov/pubmed/25209594
- DOI
- 10.1007/s00784-014-1312-4
- eISSN
- 1436-3771
- Ausgabe der Veröffentlichung
- 2
- Zeitschrift
- Clin Oral Investig
- Schlüsselwörter
- Collagen
- Synchrotrons
- Tomography, X-Ray
- Sprache
- eng
- Country
- Germany
- Paginierung
- 561 - 564
- Datum der Veröffentlichung
- 2015
- Status
- Published
- Datum, an dem der Datensatz öffentlich gemacht wurde
- 2016
- Titel
- Synchrotron-based X-ray tomographic microscopy for visualization of three-dimensional collagen matrices.
- Sub types
- Journal Article
- Research Support, Non-U.S. Gov't
- Ausgabe der Zeitschrift
- 19
Data source: PubMed
- Beziehungen:
- Property of