Optical scattering lengths in large liquid-scintillator neutrino detectors
- Publication type:
- Journal article
- Metadata:
-
- Autoren
- M Wurm
- F von Feilitzsch
- M Goeger-Neff
- M Hofmann
- T Lachenmaier
- T Lewke
- T Marrodan Undagoitia
- Q Meindl
- R Moellenberg
- L Oberauer
- W Potzel
- M Tippmann
- S Todor
- C Traunsteiner
- J Winter
- Autoren-URL
- https://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=fis-test-1&SrcAuth=WosAPI&KeyUT=WOS:000278183300013&DestLinkType=FullRecord&DestApp=WOS_CPL
- DOI
- 10.1063/1.3397322
- eISSN
- 1089-7623
- Externe Identifier
- Clarivate Analytics Document Solution ID: 603BQ
- PubMed Identifier: 20515130
- ISSN
- 0034-6748
- Ausgabe der Veröffentlichung
- 5
- Zeitschrift
- REVIEW OF SCIENTIFIC INSTRUMENTS
- Schlüsselwörter
- liquid scintillation detectors
- Mie scattering
- neutrino detection
- organic compounds
- Rayleigh scattering
- transparency
- Artikelnummer
- ARTN 053301
- Datum der Veröffentlichung
- 2010
- Status
- Published
- Titel
- Optical scattering lengths in large liquid-scintillator neutrino detectors
- Sub types
- Article
- Ausgabe der Zeitschrift
- 81
Data source: Web of Science (Lite)
- Other metadata sources:
-
- Abstract
- <jats:p>For liquid-scintillator neutrino detectors of kiloton scale, the transparency of the organic solvent is of central importance. The present paper reports on laboratory measurements of the optical scattering lengths of the organic solvents phenylxylylethane, linear alkylbenzene (LAB), and dodecane, which are under discussion for next-generation experiments such as SNO+ (Sudbury Neutrino Observatory), HanoHano, or LENA (Low Energy Neutrino Astronomy). Results comprise the wavelength range of 415–440 nm. The contributions from Rayleigh and Mie scattering as well as from absorption/re-emission processes are discussed. Based on the present results, LAB seems to be the preferred solvent for a large-volume detector.</jats:p>
- Autoren
- M Wurm
- F von Feilitzsch
- M Göger-Neff
- M Hofmann
- T Lachenmaier
- T Lewke
- T Marrodán Undagoitia
- Q Meindl
- R Möllenberg
- L Oberauer
- W Potzel
- M Tippmann
- S Todor
- C Traunsteiner
- J Winter
- DOI
- 10.1063/1.3397322
- eISSN
- 1089-7623
- ISSN
- 0034-6748
- Ausgabe der Veröffentlichung
- 5
- Zeitschrift
- Review of Scientific Instruments
- Sprache
- en
- Online publication date
- 2010
- Datum der Veröffentlichung
- 2010
- Status
- Published
- Herausgeber
- AIP Publishing
- Herausgeber URL
- http://dx.doi.org/10.1063/1.3397322
- Datum der Datenerfassung
- 2023
- Titel
- Optical scattering lengths in large liquid-scintillator neutrino detectors
- Ausgabe der Zeitschrift
- 81
Data source: Crossref
- Abstract
- For liquid-scintillator neutrino detectors of kiloton scale, the transparency of the organic solvent is of central importance. The present paper reports on laboratory measurements of the optical scattering lengths of the organic solvents phenylxylylethane, linear alkylbenzene (LAB), and dodecane, which are under discussion for next-generation experiments such as SNO+ (Sudbury Neutrino Observatory), HanoHano, or LENA (Low Energy Neutrino Astronomy). Results comprise the wavelength range of 415-440 nm. The contributions from Rayleigh and Mie scattering as well as from absorption/re-emission processes are discussed. Based on the present results, LAB seems to be the preferred solvent for a large-volume detector.
- Addresses
- Physik-Department E15, Technische Universität München, James-Franck-Str., D-85748 Garching, Germany. mwurm@ph.tum.de
- Autoren
- M Wurm
- F von Feilitzsch
- M Göger-Neff
- M Hofmann
- T Lachenmaier
- T Lewke
- T Marrodán Undagoitia
- Q Meindl
- R Möllenberg
- L Oberauer
- W Potzel
- M Tippmann
- S Todor
- C Traunsteiner
- J Winter
- DOI
- 10.1063/1.3397322
- eISSN
- 1089-7623
- Externe Identifier
- PubMed Identifier: 20515130
- Open access
- false
- ISSN
- 0034-6748
- Ausgabe der Veröffentlichung
- 5
- Zeitschrift
- The Review of scientific instruments
- Sprache
- eng
- Medium
- Paginierung
- 053301
- Datum der Veröffentlichung
- 2010
- Status
- Published
- Datum der Datenerfassung
- 2010
- Titel
- Optical scattering lengths in large liquid-scintillator neutrino detectors.
- Sub types
- Journal Article
- Ausgabe der Zeitschrift
- 81
Data source: Europe PubMed Central
- Abstract
- For liquid-scintillator neutrino detectors of kiloton scale, the transparency of the organic solvent is of central importance. The present paper reports on laboratory measurements of the optical scattering lengths of the organic solvents phenylxylylethane, linear alkylbenzene (LAB), and dodecane, which are under discussion for next-generation experiments such as SNO+ (Sudbury Neutrino Observatory), HanoHano, or LENA (Low Energy Neutrino Astronomy). Results comprise the wavelength range of 415-440 nm. The contributions from Rayleigh and Mie scattering as well as from absorption/re-emission processes are discussed. Based on the present results, LAB seems to be the preferred solvent for a large-volume detector.
- Autoren
- M Wurm
- F von Feilitzsch
- M Göger-Neff
- M Hofmann
- T Lachenmaier
- T Lewke
- T Marrodán Undagoitia
- Q Meindl
- R Möllenberg
- L Oberauer
- W Potzel
- M Tippmann
- S Todor
- C Traunsteiner
- J Winter
- Autoren-URL
- https://www.ncbi.nlm.nih.gov/pubmed/20515130
- DOI
- 10.1063/1.3397322
- eISSN
- 1089-7623
- Ausgabe der Veröffentlichung
- 5
- Zeitschrift
- Rev Sci Instrum
- Sprache
- eng
- Country
- United States
- Paginierung
- 053301
- Datum der Veröffentlichung
- 2010
- Status
- Published
- Datum, an dem der Datensatz öffentlich gemacht wurde
- 2010
- Titel
- Optical scattering lengths in large liquid-scintillator neutrino detectors.
- Sub types
- Journal Article
- Ausgabe der Zeitschrift
- 81
Data source: PubMed
- Beziehungen:
- Property of