Ion optical design of a collinear laser-negative ion beam apparatus
- Publikationstyp:
- Zeitschriftenaufsatz
- Metadaten:
-
- Autoren
- C Diehl
- K Wendt
- AO Lindahl
- P Andersson
- D Hanstorp
- Autoren-URL
- https://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=fis-test-1&SrcAuth=WosAPI&KeyUT=WOS:000291106700010&DestLinkType=FullRecord&DestApp=WOS_CPL
- DOI
- 10.1063/1.3587617
- Externe Identifier
- Clarivate Analytics Document Solution ID: 770RR
- PubMed Identifier: 21639495
- ISSN
- 0034-6748
- Ausgabe der Veröffentlichung
- 5
- Zeitschrift
- REVIEW OF SCIENTIFIC INSTRUMENTS
- Artikelnummer
- ARTN 053302
- Datum der Veröffentlichung
- 2011
- Status
- Published
- Titel
- Ion optical design of a collinear laser-negative ion beam apparatus
- Sub types
- Article
- Ausgabe der Zeitschrift
- 82
Datenquelle: Web of Science (Lite)
- Andere Metadatenquellen:
-
- Abstract
- <jats:p>An apparatus for photodetachment studies on atomic and molecular negative ions of medium up to heavy mass (M ≃ 500) has been designed and constructed. Laser and ion beams are merged in the apparatus in a collinear geometry and atoms, neutral molecules and negative ions are detected in the forward direction. The ion optical design and the components used to optimize the mass resolution and the transmission through the extended field-free interaction region are described. A 90° sector field magnet with 50 cm bending radius in combination with two slits is used for mass dispersion providing a resolution of M/ΔM≅800 for molecular ions and M/ΔM≅400 for atomic ions. The difference in mass resolution for atomic and molecular ions is attributed to different energy distributions of the sputtered ions. With 1 mm slits, transmission from the source through the interaction region to the final ion detector was determined to be about 0.14%.</jats:p>
- Autoren
- C Diehl
- K Wendt
- AO Lindahl
- P Andersson
- D Hanstorp
- DOI
- 10.1063/1.3587617
- eISSN
- 1089-7623
- ISSN
- 0034-6748
- Ausgabe der Veröffentlichung
- 5
- Zeitschrift
- Review of Scientific Instruments
- Sprache
- en
- Online publication date
- 2011
- Datum der Veröffentlichung
- 2011
- Status
- Published
- Herausgeber
- AIP Publishing
- Herausgeber URL
- http://dx.doi.org/10.1063/1.3587617
- Datum der Datenerfassung
- 2023
- Titel
- Ion optical design of a collinear laser-negative ion beam apparatus
- Ausgabe der Zeitschrift
- 82
Datenquelle: Crossref
- Abstract
- An apparatus for photodetachment studies on atomic and molecular negative ions of medium up to heavy mass (M ≃ 500) has been designed and constructed. Laser and ion beams are merged in the apparatus in a collinear geometry and atoms, neutral molecules and negative ions are detected in the forward direction. The ion optical design and the components used to optimize the mass resolution and the transmission through the extended field-free interaction region are described. A 90° sector field magnet with 50 cm bending radius in combination with two slits is used for mass dispersion providing a resolution of M∕ΔM≅800 for molecular ions and M∕ΔM≅400 for atomic ions. The difference in mass resolution for atomic and molecular ions is attributed to different energy distributions of the sputtered ions. With 1 mm slits, transmission from the source through the interaction region to the final ion detector was determined to be about 0.14%.
- Addresses
- Institut für Physik, Johannes Gutenberg-Universität, Mainz, D-55099 Mainz, Germany.
- Autoren
- C Diehl
- K Wendt
- AO Lindahl
- P Andersson
- D Hanstorp
- DOI
- 10.1063/1.3587617
- eISSN
- 1089-7623
- Externe Identifier
- PubMed Identifier: 21639495
- Open access
- false
- ISSN
- 0034-6748
- Ausgabe der Veröffentlichung
- 5
- Zeitschrift
- The Review of scientific instruments
- Sprache
- eng
- Medium
- Paginierung
- 053302
- Datum der Veröffentlichung
- 2011
- Status
- Published
- Datum der Datenerfassung
- 2011
- Titel
- Ion optical design of a collinear laser-negative ion beam apparatus.
- Sub types
- Journal Article
- Ausgabe der Zeitschrift
- 82
Datenquelle: Europe PubMed Central
- Abstract
- An apparatus for photodetachment studies on atomic and molecular negative ions of medium up to heavy mass (M ≃ 500) has been designed and constructed. Laser and ion beams are merged in the apparatus in a collinear geometry and atoms, neutral molecules and negative ions are detected in the forward direction. The ion optical design and the components used to optimize the mass resolution and the transmission through the extended field-free interaction region are described. A 90° sector field magnet with 50 cm bending radius in combination with two slits is used for mass dispersion providing a resolution of M∕ΔM≅800 for molecular ions and M∕ΔM≅400 for atomic ions. The difference in mass resolution for atomic and molecular ions is attributed to different energy distributions of the sputtered ions. With 1 mm slits, transmission from the source through the interaction region to the final ion detector was determined to be about 0.14%.
- Autoren
- C Diehl
- K Wendt
- AO Lindahl
- P Andersson
- D Hanstorp
- Autoren-URL
- https://www.ncbi.nlm.nih.gov/pubmed/21639495
- DOI
- 10.1063/1.3587617
- eISSN
- 1089-7623
- Ausgabe der Veröffentlichung
- 5
- Zeitschrift
- Rev Sci Instrum
- Sprache
- eng
- Country
- United States
- Paginierung
- 053302
- Datum der Veröffentlichung
- 2011
- Status
- Published
- Datum, an dem der Datensatz öffentlich gemacht wurde
- 2011
- Titel
- Ion optical design of a collinear laser-negative ion beam apparatus.
- Sub types
- Journal Article
- Ausgabe der Zeitschrift
- 82
Datenquelle: PubMed
- Beziehungen:
- Eigentum von