Assessment of hypoglycaemia awareness using continuous glucose monitoring
- Publikationstyp:
- Zeitschriftenaufsatz
- Metadaten:
-
- Autoren
- Thomas Kubiak
- Norbert Hermanns
- HJ Schreckling
- Bernhard Kulzer
- Thomas Haak
- Sammlungen
- metadata
- ISSN
- 1464-5491
- Ausgabe der Veröffentlichung
- 5
- Zeitschrift
- Diabetic medicine
- Schlüsselwörter
- 150 Psychologie
- 150 Psychology
- Sprache
- eng
- Paginierung
- Seiten: 487 - 490
- Datum der Veröffentlichung
- 2004
- Herausgeber
- Wiley- Blackwell
- Herausgeber URL
- http://dx.doi.org/10.1111/j.1464-5491.2004.1136.x
- Datum der Datenerfassung
- 2020
- Datum, an dem der Datensatz öffentlich gemacht wurde
- 2020
- Zugang
- Public
- Titel
- Assessment of hypoglycaemia awareness using continuous glucose monitoring
- Ausgabe der Zeitschrift
- 21
Datenquelle: METADATA.UB
- Andere Metadatenquellen:
-
- Autoren
- T Kubiak
- N Hermanns
- HJ Schreckling
- B Kulzer
- T Haak
- Autoren-URL
- https://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=fis-test-1&SrcAuth=WosAPI&KeyUT=WOS:000221243700014&DestLinkType=FullRecord&DestApp=WOS_CPL
- DOI
- 10.1111/j.1464-5491.2004.1136.x
- eISSN
- 1464-5491
- Externe Identifier
- Clarivate Analytics Document Solution ID: 818KJ
- PubMed Identifier: 15089796
- ISSN
- 0742-3071
- Ausgabe der Veröffentlichung
- 5
- Zeitschrift
- DIABETIC MEDICINE
- Schlüsselwörter
- Type 1 diabetes
- hypoglycaemia
- hypoglycaemia awareness
- continuous glucose monitoring
- Paginierung
- 487 - 490
- Datum der Veröffentlichung
- 2004
- Status
- Published
- Titel
- Assessment of hypoglycaemia awareness using continuous glucose monitoring
- Sub types
- Article
- Ausgabe der Zeitschrift
- 21
Datenquelle: Web of Science (Lite)
- Abstract
- <jats:title>Abstract</jats:title><jats:p><jats:bold>Aims </jats:bold> To investigate the possibility of assessing hypoglycaemia awareness in patients with Type 1 diabetes using continuous glucose monitoring.</jats:p><jats:p><jats:bold>Methods </jats:bold> Twenty patients with Type 1 diabetes were investigated. Ten patients with Type 1 diabetes and strongly impaired hypoglycaemia awareness were compared with 10 patients with intact hypoglycaemia awareness regarding quality of hypoglycaemia perception (number of undetected hypoglycaemic episodes per 24 h, glucose level < 3.3 mmol/l). Hypoglycaemia detection was assessed using the event function of the Continuous Glucose Monitoring System (CGMS™; Medtronic MiniMed®, Northridge, CA, USA). Patients were instructed to enter an event upon suspecting being hypoglycaemic.</jats:p><jats:p><jats:bold>Results </jats:bold> Satisfactory CGMS performance could be achieved [mean <jats:italic>r</jats:italic> = 0.893 between calibration measurements and CGMS data, mean absolute difference (MAD) = 20.6%], although artefacts were observable and had to be controlled. Hypoglycaemia unaware patients showed a significantly higher total number of hypoglycaemic episodes (<jats:italic>P</jats:italic> < 0.05), number of undetected hypoglycaemic episodes (<jats:italic>P</jats:italic> < 0.01), and mean glucose levels (<jats:italic>P</jats:italic> < 0.05). Even in aware patients, undetected hypoglycaemia was observable. No significant differences regarding occurrence of nocturnal hypoglycaemia were observable.</jats:p><jats:p><jats:bold>Conclusions </jats:bold> The possibility of direct assessment of hypoglycaemia awareness using continuous glucose monitoring was demonstrated. Its application in clinical practice could be of use for assessing hypoglycaemia perception and evaluating the impact of treatment changes on hypoglycaemia awareness.</jats:p>
- Autoren
- T Kubiak
- N Hermanns
- HJ Schreckling
- B Kulzer
- T Haak
- DOI
- 10.1111/j.1464-5491.2004.1136.x
- eISSN
- 1464-5491
- ISSN
- 0742-3071
- Ausgabe der Veröffentlichung
- 5
- Zeitschrift
- Diabetic Medicine
- Sprache
- en
- Online publication date
- 2004
- Paginierung
- 487 - 490
- Datum der Veröffentlichung
- 2004
- Status
- Published
- Herausgeber
- Wiley
- Herausgeber URL
- http://dx.doi.org/10.1111/j.1464-5491.2004.1136.x
- Datum der Datenerfassung
- 2023
- Titel
- Assessment of hypoglycaemia awareness using continuous glucose monitoring
- Ausgabe der Zeitschrift
- 21
Datenquelle: Crossref
- Abstract
- <h4>Aims</h4>To investigate the possibility of assessing hypoglycaemia awareness in patients with Type 1 diabetes using continuous glucose monitoring.<h4>Methods</h4>Twenty patients with Type 1 diabetes were investigated. Ten patients with Type 1 diabetes and strongly impaired hypoglycaemia awareness were compared with 10 patients with intact hypoglycaemia awareness regarding quality of hypoglycaemia perception (number of undetected hypoglycaemic episodes per 24 h, glucose level < 3.3 mmol/l). Hypoglycaemia detection was assessed using the event function of the Continuous Glucose Monitoring System (CGMS; Medtronic MiniMed, Northridge, CA, USA). Patients were instructed to enter an event upon suspecting being hypoglycaemic.<h4>Results</h4>Satisfactory CGMS performance could be achieved [mean r = 0.893 between calibration measurements and CGMS data, mean absolute difference (MAD) = 20.6%], although artefacts were observable and had to be controlled. Hypoglycaemia unaware patients showed a significantly higher total number of hypoglycaemic episodes (P < 0.05), number of undetected hypoglycaemic episodes (P < 0.01), and mean glucose levels (P < 0.05). Even in aware patients, undetected hypoglycaemia was observable. No significant differences regarding occurrence of nocturnal hypoglycaemia were observable.<h4>Conclusions</h4>The possibility of direct assessment of hypoglycaemia awareness using continuous glucose monitoring was demonstrated. Its application in clinical practice could be of use for assessing hypoglycaemia perception and evaluating the impact of treatment changes on hypoglycaemia awareness.
- Addresses
- Research Institute of the Diabetes Academy Mergentheim, Th-Klotzbuecher-Strasse-12, D-97980 Bad Mergentheim, Germany. kubiak@diabetes-zentrum.de
- Autoren
- T Kubiak
- N Hermanns
- HJ Schreckling
- B Kulzer
- T Haak
- DOI
- 10.1111/j.1464-5491.2004.1136.x
- eISSN
- 1464-5491
- Externe Identifier
- PubMed Identifier: 15089796
- Open access
- false
- ISSN
- 0742-3071
- Ausgabe der Veröffentlichung
- 5
- Zeitschrift
- Diabetic medicine : a journal of the British Diabetic Association
- Schlüsselwörter
- Humans
- Diabetes Mellitus, Type 1
- Hypoglycemia
- Insulin
- Hypoglycemic Agents
- Blood Glucose Self-Monitoring
- Pilot Projects
- Awareness
- Adult
- Middle Aged
- Female
- Male
- Sprache
- eng
- Medium
- Paginierung
- 487 - 490
- Datum der Veröffentlichung
- 2004
- Status
- Published
- Datum der Datenerfassung
- 2004
- Titel
- Assessment of hypoglycaemia awareness using continuous glucose monitoring.
- Sub types
- Journal Article
- Ausgabe der Zeitschrift
- 21
Datenquelle: Europe PubMed Central
- Abstract
- AIMS: To investigate the possibility of assessing hypoglycaemia awareness in patients with Type 1 diabetes using continuous glucose monitoring. METHODS: Twenty patients with Type 1 diabetes were investigated. Ten patients with Type 1 diabetes and strongly impaired hypoglycaemia awareness were compared with 10 patients with intact hypoglycaemia awareness regarding quality of hypoglycaemia perception (number of undetected hypoglycaemic episodes per 24 h, glucose level < 3.3 mmol/l). Hypoglycaemia detection was assessed using the event function of the Continuous Glucose Monitoring System (CGMS; Medtronic MiniMed, Northridge, CA, USA). Patients were instructed to enter an event upon suspecting being hypoglycaemic. RESULTS: Satisfactory CGMS performance could be achieved [mean r = 0.893 between calibration measurements and CGMS data, mean absolute difference (MAD) = 20.6%], although artefacts were observable and had to be controlled. Hypoglycaemia unaware patients showed a significantly higher total number of hypoglycaemic episodes (P < 0.05), number of undetected hypoglycaemic episodes (P < 0.01), and mean glucose levels (P < 0.05). Even in aware patients, undetected hypoglycaemia was observable. No significant differences regarding occurrence of nocturnal hypoglycaemia were observable. CONCLUSIONS: The possibility of direct assessment of hypoglycaemia awareness using continuous glucose monitoring was demonstrated. Its application in clinical practice could be of use for assessing hypoglycaemia perception and evaluating the impact of treatment changes on hypoglycaemia awareness.
- Autoren
- T Kubiak
- N Hermanns
- HJ Schreckling
- B Kulzer
- T Haak
- Autoren-URL
- https://www.ncbi.nlm.nih.gov/pubmed/15089796
- DOI
- 10.1111/j.1464-5491.2004.1136.x
- ISSN
- 0742-3071
- Ausgabe der Veröffentlichung
- 5
- Zeitschrift
- Diabet Med
- Schlüsselwörter
- Adult
- Awareness
- Blood Glucose Self-Monitoring
- Diabetes Mellitus, Type 1
- Female
- Humans
- Hypoglycemia
- Hypoglycemic Agents
- Insulin
- Male
- Middle Aged
- Pilot Projects
- Sprache
- eng
- Country
- England
- Paginierung
- 487 - 490
- PII
- DME1136
- Datum der Veröffentlichung
- 2004
- Status
- Published
- Datum, an dem der Datensatz öffentlich gemacht wurde
- 2004
- Titel
- Assessment of hypoglycaemia awareness using continuous glucose monitoring.
- Sub types
- Journal Article
- Ausgabe der Zeitschrift
- 21
Datenquelle: PubMed
- Beziehungen:
- Eigentum von