Measurements and simulations of Cherenkov light in lead fluoride crystals
- Publikationstyp:
- Zeitschriftenaufsatz
- Metadaten:
-
- Autoren
- P Achenbach
- S Baunack
- K Grimm
- T Hammel
- D von Harrach
- AL Ginja
- FE Maas
- E Schilling
- H Ströher
- Autoren-URL
- https://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=fis-test-1&SrcAuth=WosAPI&KeyUT=WOS:000169449000004&DestLinkType=FullRecord&DestApp=WOS_CPL
- DOI
- 10.1016/S0168-9002(01)00668-4
- Externe Identifier
- Clarivate Analytics Document Solution ID: 445GD
- ISSN
- 0168-9002
- Ausgabe der Veröffentlichung
- 2-3
- Zeitschrift
- NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
- Schlüsselwörter
- Cherenkov counters
- lead fluoride
- light yield
- photoelectron distributions
- Monte Carlo simulations
- Paginierung
- 318 - 328
- Datum der Veröffentlichung
- 2001
- Status
- Published
- Titel
- Measurements and simulations of Cherenkov light in lead fluoride crystals
- Sub types
- Article
- Ausgabe der Zeitschrift
- 465
Datenquelle: Web of Science (Lite)
- Andere Metadatenquellen:
-
- Autoren
- P Achenbach
- S Baunack
- K Grimm
- T Hammel
- D von Harrach
- A Lopes Ginja
- FE Maas
- E Schilling
- H Ströher
- DOI
- 10.1016/s0168-9002(01)00668-4
- ISSN
- 0168-9002
- Ausgabe der Veröffentlichung
- 2-3
- Zeitschrift
- Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Sprache
- en
- Paginierung
- 318 - 328
- Datum der Veröffentlichung
- 2001
- Status
- Published
- Herausgeber
- Elsevier BV
- Herausgeber URL
- http://dx.doi.org/10.1016/s0168-9002(01)00668-4
- Datum der Datenerfassung
- 2019
- Titel
- Measurements and simulations of Cherenkov light in lead fluoride crystals
- Ausgabe der Zeitschrift
- 465
Datenquelle: Crossref
- Abstract
- The anticipated use of more than one thousand lead fluoride (PbF2) crystals as a fast and compact Cherenkov calorimeter material in a parity violation experiment at MAMI stimulated the investigation of the light yield (L.Y.) of these crystals. The number of photoelectrons (p.e.) per MeV deposited energy has been determined with a hybrid photomultiplier tube (HPMT). In response to radioactive sources a L.Y. between 1.7 and 1.9 p.e./MeV was measured with 4% statistical and 5% systematic error. The L.Y. optimization with appropriate wrappings and couplings was investigated by means of the HPMT. Furthermore, a fast Monte Carlo simulation based on the GEANT code was employed to calculate the characteristics of Cherenkov light in the PbF2 crystals. The computing time was reduced by a factor of 50 compared to the regular photon tracking method by implementing detection probabilities as a three-dimensional look-up table. For a single crystal a L.Y. of 2.1 p.e./MeV was calculated. The corresponding detector response to electrons between 10 and 1000 MeV was highly linear with a variation smaller than 1%.
- Autoren
- P Achenbach
- S Baunack
- K Grimm
- T Hammel
- D von Harrach
- A Lopes Ginja
- FE Maas
- E Schilling
- H Stroeher
- Autoren-URL
- http://arxiv.org/abs/nucl-ex/0108019v1
- Zeitschrift
- Nucl.Instrum.Meth.A
- Schlüsselwörter
- nucl-ex
- nucl-ex
- Paginierung
- 318 - 328
- Datum der Veröffentlichung
- 2001
- Herausgeber URL
- http://dx.doi.org/10.1016/S0168-9002(01)00668-4
- Datum der Datenerfassung
- 2001
- Datum, an dem der Datensatz öffentlich gemacht wurde
- 2001
- Titel
- Measurements and simulations of Cherenkov light in lead fluoride crystals
- Ausgabe der Zeitschrift
- 465
Files
0108019v1.pdf
Datenquelle: arXiv
- Beziehungen:
- Eigentum von