Long-time stability of a low-energy electron diffraction spin polarization analyzer for magnetic imaging
- Publikationstyp:
- Zeitschriftenaufsatz
- Metadaten:
-
- Autoren
- F Lofink
- S Hankemeier
- R Froemter
- J Kirschner
- HP Oepen
- Autoren-URL
- https://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=fis-test-1&SrcAuth=WosAPI&KeyUT=WOS:000301566600032&DestLinkType=FullRecord&DestApp=WOS_CPL
- DOI
- 10.1063/1.3685629
- eISSN
- 1089-7623
- Externe Identifier
- Clarivate Analytics Document Solution ID: 909LS
- PubMed Identifier: 22380100
- ISSN
- 0034-6748
- Ausgabe der Veröffentlichung
- 2
- Zeitschrift
- REVIEW OF SCIENTIFIC INSTRUMENTS
- Artikelnummer
- ARTN 023708
- Datum der Veröffentlichung
- 2012
- Status
- Published
- Titel
- Long-time stability of a low-energy electron diffraction spin polarization analyzer for magnetic imaging
- Sub types
- Article
- Ausgabe der Zeitschrift
- 83
Datenquelle: Web of Science (Lite)
- Andere Metadatenquellen:
-
- Abstract
- <jats:p>The time stability of a polarization analyzer that is used for imaging of magnetic structures in a scanning electron microscope with spin polarization analysis (spin-SEM or SEMPA) is investigated. The detector is based on the diffraction of low-energy electrons at a W(100) crystal at 104.5 eV (LEED detector). Due to the adsorption of hydrogen from residual gas, a change of the scattering conditions is found that causes an angular shift of the LEED beams as well as changes of intensity. The quality factor, which describes the efficiency of the detector in SEMPA application, however, is found to be almost constant up to a hydrogen coverage of θ ≈ 0.25. This gives stable working conditions within roughly 1 h at vacuum conditions of 10−10 mbar.</jats:p>
- Autoren
- F Lofink
- S Hankemeier
- R Frömter
- J Kirschner
- HP Oepen
- DOI
- 10.1063/1.3685629
- eISSN
- 1089-7623
- ISSN
- 0034-6748
- Ausgabe der Veröffentlichung
- 2
- Zeitschrift
- Review of Scientific Instruments
- Sprache
- en
- Online publication date
- 2012
- Datum der Veröffentlichung
- 2012
- Status
- Published
- Herausgeber
- AIP Publishing
- Herausgeber URL
- http://dx.doi.org/10.1063/1.3685629
- Datum der Datenerfassung
- 2023
- Titel
- Long-time stability of a low-energy electron diffraction spin polarization analyzer for magnetic imaging
- Ausgabe der Zeitschrift
- 83
Datenquelle: Crossref
- Abstract
- The time stability of a polarization analyzer that is used for imaging of magnetic structures in a scanning electron microscope with spin polarization analysis (spin-SEM or SEMPA) is investigated. The detector is based on the diffraction of low-energy electrons at a W(100) crystal at 104.5 eV (LEED detector). Due to the adsorption of hydrogen from residual gas, a change of the scattering conditions is found that causes an angular shift of the LEED beams as well as changes of intensity. The quality factor, which describes the efficiency of the detector in SEMPA application, however, is found to be almost constant up to a hydrogen coverage of θ ≈ 0.25. This gives stable working conditions within roughly 1 h at vacuum conditions of 10(-10) mbar.
- Addresses
- Institut für Angewandte Physik, Universität Hamburg, Jungiusstr. 11, 20355 Hamburg, Germany. flofink@physik.uni-hamburg.de
- Autoren
- F Lofink
- S Hankemeier
- R Frömter
- J Kirschner
- HP Oepen
- DOI
- 10.1063/1.3685629
- eISSN
- 1089-7623
- Externe Identifier
- PubMed Identifier: 22380100
- Open access
- false
- ISSN
- 0034-6748
- Ausgabe der Veröffentlichung
- 2
- Zeitschrift
- The Review of scientific instruments
- Sprache
- eng
- Medium
- Paginierung
- 023708
- Datum der Veröffentlichung
- 2012
- Status
- Published
- Datum der Datenerfassung
- 2012
- Titel
- Long-time stability of a low-energy electron diffraction spin polarization analyzer for magnetic imaging.
- Sub types
- Journal Article
- Ausgabe der Zeitschrift
- 83
Datenquelle: Europe PubMed Central
- Abstract
- The time stability of a polarization analyzer that is used for imaging of magnetic structures in a scanning electron microscope with spin polarization analysis (spin-SEM or SEMPA) is investigated. The detector is based on the diffraction of low-energy electrons at a W(100) crystal at 104.5 eV (LEED detector). Due to the adsorption of hydrogen from residual gas, a change of the scattering conditions is found that causes an angular shift of the LEED beams as well as changes of intensity. The quality factor, which describes the efficiency of the detector in SEMPA application, however, is found to be almost constant up to a hydrogen coverage of θ ≈ 0.25. This gives stable working conditions within roughly 1 h at vacuum conditions of 10(-10) mbar.
- Autoren
- F Lofink
- S Hankemeier
- R Frömter
- J Kirschner
- HP Oepen
- Autoren-URL
- https://www.ncbi.nlm.nih.gov/pubmed/22380100
- DOI
- 10.1063/1.3685629
- eISSN
- 1089-7623
- Ausgabe der Veröffentlichung
- 2
- Zeitschrift
- Rev Sci Instrum
- Sprache
- eng
- Country
- United States
- Paginierung
- 023708
- Datum der Veröffentlichung
- 2012
- Status
- Published
- Datum, an dem der Datensatz öffentlich gemacht wurde
- 2012
- Titel
- Long-time stability of a low-energy electron diffraction spin polarization analyzer for magnetic imaging.
- Sub types
- Journal Article
- Ausgabe der Zeitschrift
- 83
Datenquelle: PubMed
- Beziehungen:
- Eigentum von