Construction and applications of an atomic magnetic gradiometer based on nonlinear magneto-optical rotation
- Publikationstyp:
- Zeitschriftenaufsatz
- Metadaten:
-
- Autoren
- Shoujun Xu
- Simon M Rochester
- Valeriy V Yashchuk
- Marcus H Donaldson
- Dmitry Budker
- Autoren-URL
- https://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=fis-test-1&SrcAuth=WosAPI&KeyUT=WOS:000240035800006&DestLinkType=FullRecord&DestApp=WOS_CPL
- DOI
- 10.1063/1.2336087
- eISSN
- 1089-7623
- Externe Identifier
- Clarivate Analytics Document Solution ID: 077NH
- ISSN
- 0034-6748
- Ausgabe der Veröffentlichung
- 8
- Zeitschrift
- REVIEW OF SCIENTIFIC INSTRUMENTS
- Artikelnummer
- ARTN 083106
- Datum der Veröffentlichung
- 2006
- Status
- Published
- Titel
- Construction and applications of an atomic magnetic gradiometer based on nonlinear magneto-optical rotation
- Sub types
- Article
- Ausgabe der Zeitschrift
- 77
Datenquelle: Web of Science (Lite)
- Andere Metadatenquellen:
-
- Abstract
- <jats:p>We report on the design, characterization, and applications of a sensitive atomic magnetic gradiometer. The device is based on nonlinear magneto-optical rotation in alkali-metal (Rb87) vapor and uses frequency-modulated laser light. The magnetic field produced by a sample is detected by measuring the frequency of a resonance in optical rotation that arises when the modulation frequency equals twice the Larmor precession frequency of the Rb atoms. The gradiometer consists of two atomic magnetometers. The rotation of light polarization in each magnetometer is detected with a balanced polarimeter. The sensitivity of the gradiometer is 0.8nG∕Hz1∕2 for near-dc (0.1Hz) magnetic fields, with a base line of 2.5cm. For applications in nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI), a long solenoid that pierces the magnetic shields provides an ∼0.5G leading field for the nuclear spins in the sample. Our apparatus is particularly suited for remote detection of NMR and MRI. We demonstrate a point-by-point free induction decay measurement and a spin echo reconstructed with a pulse sequence similar to the Carr-Purcell-Meiboom-Gill pulse. Additional applications and future improvements are also discussed.</jats:p>
- Autoren
- Shoujun Xu
- Simon M Rochester
- Valeriy V Yashchuk
- Marcus H Donaldson
- Dmitry Budker
- DOI
- 10.1063/1.2336087
- eISSN
- 1089-7623
- ISSN
- 0034-6748
- Ausgabe der Veröffentlichung
- 8
- Zeitschrift
- Review of Scientific Instruments
- Sprache
- en
- Online publication date
- 2006
- Datum der Veröffentlichung
- 2006
- Status
- Published
- Herausgeber
- AIP Publishing
- Herausgeber URL
- http://dx.doi.org/10.1063/1.2336087
- Datum der Datenerfassung
- 2023
- Titel
- Construction and applications of an atomic magnetic gradiometer based on nonlinear magneto-optical rotation
- Ausgabe der Zeitschrift
- 77
Datenquelle: Crossref
- Beziehungen:
- Eigentum von